Table 22.

POST Memory Error 3-Beep Codes

 

 

 

 

 

 

 

 

 

 

 

Debug port

 

Diagnostic LED Decoder

 

 

 

 

 

 

 

 

 

Beep

80h error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G=Green, R=Red, A=Amber

 

 

 

 

 

 

 

 

Code

indicators

 

 

 

 

Meanings

 

 

FRU/Action

 

 

 

 

 

 

 

 

 

 

 

 

Hi

 

 

 

 

Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

00h

Off

Off

 

Off

Off

 

 

No memory was found in

 

 

1.

Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

the system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

01h

Off

Off

 

Off

G

 

 

Memory mixed type

 

 

1.

Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

detected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

02h

Off

Off

 

G

Off

 

 

EDO is not supported.

 

1. Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

03h

Off

Off

 

G

G

 

 

First row memory test

 

 

1.

Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

failure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

04h

Off

G

 

Off

Off

 

 

Mismatched DIMMs in a

 

 

1.

Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

row.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

05h

Off

G

 

Off

G

 

 

Base memory test failure.

 

1. Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

06h

Off

G

 

G

Off

 

 

Failure on decompressing

 

 

1.

Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

post module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

07h-0Dh

Off

 

G

 

G

G

 

 

Generic memory error.

1. Check DIMMs

 

 

 

 

G

 

Off

 

Off

Off

 

 

 

 

 

 

 

G

 

Off

 

Off

G

 

 

 

 

 

 

 

 

 

 

G

 

Off

 

G

Off

 

 

 

 

 

 

 

G

 

Off

 

G

G

 

 

 

 

 

 

 

 

 

 

G

 

G

 

Off

Off

 

 

 

 

 

 

 

G

 

G

 

Off

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

0Eh

G

G

 

G

Off

 

SMBUS protocol error.

 

1. Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Check Firmware

 

 

 

 

 

 

 

 

 

 

 

3

0F-FFh

All other combinations

 

Generic memory error.

1. Check DIMMs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POST Error Codes, Messages and FRU to Failure Information