Power Supplies

The power supply cage shown in Figure 8 is accessed from the rear of the chassis. The power supply cage supports up to two hot-swap 350 W DC input power supplies in a (1 + 1) redundant configuration. A power supply filler) for the empty power supply site is supplied for systems without redundancy.

The power supply is NEBS certified.

OM14224

Figure 8. Non-redundant DC-Power Supply Subsystem (Filler Module shown at Left)

DC Power Subsystem

This section defines the features of the DC input switching power subsystem.

Features

•350 W output capability in full DC input voltage range

•“Power Good” indication LEDs

•Predictive failure warning

•Internal cooling fans with multi-speed capability

•Remote sense of 3.3 Volt, 5 Volt, and 12 Volt DC outputs

•“DC_OK” circuitry for brown out protection and recovery

•Built-in load sharing capability

•Built-in overloading protection capability

•Onboard field replaceable unit (FRU) information

•I2C interface for server management functions

•Integral handle for insertion/extraction

Chassis Description