DASD
NMI
PCIPS SP
CNFG
MEM
CPU
FAN
VRM
OVER SPEC
TEMP
Light PathDiagnostics
BRD
LOG LINK
RAID
REMIND
NMI button
Reset button
Remind
button
Check point
code display
vRemind button: This button places the system-error LED on the front panel into
Remind mode. In Remind mode, the system-error LED flashes once every 2
seconds until the problem is corrected, the server is restarted, or a new problem
occurs.
By placing the system-error LED indicator in Remind mode, you acknowledge
that you are aware of the last failure but will not take immediate action to
correct the problem. The remind function is controlled by the IMM.
vNMI button: Press this button to force a nonmaskable interrupt to the
microprocessor,if you are directed to do so by IBM service.
vReset button: Press this button to reset the server and run the power-on self-test
(POST). Youmight have to use a pen or the end of a straightened paper clip to
press the button. The reset button is in the lower-right corner of the light path
diagnostics panel.
For more information about light path diagnostics, see the Problem Determination
and Service Guide on the IBM Documentation CD.
Rear view
The following illustration shows the connectors on the rear of the server.
Power-cord connector: Connect the power cord to this connector.
16 IBM System x3850 X5 and x3950 X5 Types7145, 7146, 7143, and 7191: Installation and User's Guide