IBM B50 manual Specifications, Dimensions, Weight, Maximum Support Capacity Horizontal Position

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 22
Image 22
Specifications

Specifications

The mechanical packaging, cooling, power supply, and environmental requirements for the workstation are as follows:

Dimensions

In horizontal orientation, the dimensions are:

Height - 88.0 mm (3.5 inches)

Width - 447.0 mm (17.6 inches)

Depth - 612.0 mm (24.1 inches) Minimum

Depth - 751.8 mm (29.6 inches) Maximum (includes covers and cables)

Weight

14.5 kg (32 lb) Minimum to 15.9 kg (35 lb) Maximum

Maximum Support Capacity (Horizontal Position)

27.3 kg (60 lbs)

Operating Environment - Class C

Temperature - 10° to 40°C (50° to 104°F) 1

Humidity - 8% to 80% noncondensing

Wet Bulb - 27 degrees C (80 degrees F) operating and nonoperating

2

 

Maximum Altitude - 2135 m (7000 feet)

Power Source Loading

0.3k VA typical

0.5k VA maximum

1The upper limit of the dry bulb temperature must be derated 1° C per 137m (450 ft.) above 915m (3000 ft.).

2The upper limit of the wet bulb temperature must be derated 1° C per 274m (900 ft.) above 305m (1000 ft.).

1-47046 Model B50 Service Guide

Page 22
Image 22
IBM B50 Specifications, Dimensions, Weight, Maximum Support Capacity Horizontal Position, Operating Environment - Class C