IBM B50 manual Diagnostics Information for Multiple Bus, Information for Multiple Bus Systems

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 32
Image 32

Use the following table to determine your starting point.

Symptom

 

Action

 

 

 

 

 

 

 

Service Actions

 

 

 

 

 

 

 

You have parts to exchange or a corrective

 

1. Go to Chapter 7, “Removal and

 

 

action to perform.

 

Replacement Procedures” on page 7-1.

 

 

2. Go to "MAP 0410: Repair Checkout

" in the

 

 

Diagnostics Information for Multiple Bus

 

 

Systems.

 

 

 

 

 

 

 

You need to verify that a part exchange or

 

Go to "MAP 0410: Repair Checkout

 

" in the

corrective action corrected the problem.

 

Diagnostics Information for Multiple Bus

 

 

Systems.

 

 

 

 

 

 

 

You need to verify correct system operation.

 

Go to "MAP 0410: Repair Checkout

 

" in the

 

 

Diagnostics Information for Multiple Bus

 

 

Systems.

 

 

 

 

 

 

System Stops or hangs with alternating numbers displayed in the Operator Panel display.

 

 

 

 

The Operator Panel display alternates between

 

Record both codes. Go to the entry for "E1FD"

the code "E1FD" and another "Exxx" code.

 

on page 3-23.

 

 

 

 

 

The Operator Panel display alternates between

 

Record the error codes. Go to the entry for

the codes "E1DE" and "E1AD".

 

"E1DE" on page 3-21,

 

 

 

 

 

 

System Stops with an Error or Checkpoint Code Displayed

 

 

 

 

The system stops with an 8-digit error code

 

Record the error code. Go to Chapter 3, “Error

starting with the number "2" displayed on the

 

Code to FRU Index” on page 3-1.

 

 

system console.

 

 

 

 

 

 

 

The system stops and a 4-digit number

 

Go to “MAP 1540: Minimum Configuration” on

beginning with the characters "FF" is displayed

 

page 2-17.

 

 

in the operator panel display.

 

 

 

 

 

 

 

 

 

The system stops and a 4-digit number

 

Record the code. Go to “Firmware

 

 

beginning with the character "E" is displayed in

 

Checkpoints” on page 3-14.

 

 

the operator panel display.

 

 

 

 

 

 

 

The system stops and a 4-digit number not

 

Record SRN 101-xxx, where xxx is the last

beginning with the characters "FF" or "E" is

 

three digits of the 4-digit number displayed, then

displayed in the operator panel display.

 

go to the "Fast Path MAP" in the

Diagnostics

 

 

Information for Multiple Bus Systems.

 

 

 

The system stops and a 3-digit number is

 

If the number is 000, 185 or 888, go to “MAP

displayed in the operator panel display.

 

1540: Minimum Configuration” on page 2-17.

 

 

Record SRN 101-xxx, where xxx is the number

 

 

displayed, then go to the "Fast Path MAP" in

 

 

Diagnostics Information for Multiple Bus

 

 

Systems.

 

 

 

 

 

 

 

2-27046 Model B50 Service Guide

Page 32
Image 32