Checkpoint

Description

Repair Action

(hex)

 

 

 

 

 

E207

Setup Data gather

Replace system board (see note 3 on page 2-1).

 

mode and 64/32-bit

 

 

mode on PCG

 

 

 

 

E208

Assign bus number

Replace system board (see note 3 on page 2-1).

 

on PCG

 

 

 

 

E209

Assign PCI I/O

Replace system board (see note 3 on page 2-1).

 

addresses on PCI

 

 

 

 

E20A

Assign PCI I/O

Replace system board (see note 3 on page 2-1).

 

addresses on PCG

 

 

 

 

E20B

Check MCERs stuck

Replace system board (see note 3 on page 2-1).

 

at fault

 

 

 

 

E20C

Testing L2 cache

Replace system board (see note 3 on page 2-1).

 

 

 

E210

Processors L1 data

Replace system board (see note 3 on page 2-1).

 

cache array test

 

 

fails. System Hangs.

 

 

 

 

E211

IPL ROS CRC

Replace system board (see note 3 on page 2-1).

 

checking

 

 

 

 

E212

Processor POST

Replace system board (see note 3 on page 2-1).

 

 

 

E213

Initial memory

See “MAP 1240: Memory Problem Resolution” on

 

configuration

page 2-9

 

 

 

E214

Memory test

See “MAP 1240: Memory Problem Resolution” on

 

 

page 2-9

 

 

 

E216

Copy ROS into

See “MAP 1240: Memory Problem Resolution” on

 

RAM. Set up

page 2-9

 

Translation and C

 

 

environment

 

 

 

 

E21A

System has some

See “Unresolved problems” on page 3-26

 

good memory

 

 

 

 

E220

Final memory

Replace system board (see note 3 on page 2-1).

 

configuration

See “MAP 1240: Memory Problem Resolution” on

 

 

 

 

page 2-9

 

 

 

E240

Set up Winbond ISA

Replace system board (see note 3 on page 2-1).

 

bridge

 

 

 

 

E241

Reset PCI Bus

Replace system board (see note 3 on page 2-1).

 

 

 

E242

Initialize ISA DMA

Replace system board (see note 3 on page 2-1).

 

channel

 

 

 

 

E243

Set up Grackle

Replace system board (see note 3 on page 2-1).

 

configuration

 

 

registers

 

 

 

 

3-247046 Model B50 Service Guide

Page 88
Image 88
IBM B50 manual Ipl Ros Crc