Step 1540-20
1.Insert the diagnostic
2.Turn off the power.
3.Connect one of the external devices that was disconnected in “Step
Note: If the device has a power switch, ensure that the device is turned on.
a.SCSI devices connected to the external SCSI connector
b.Device connected to serial 1 c. Device connected to serial 2
d. Device connected to parallel port 4. Turn on the power.
5. When the keyboard indicator is displayed (the word keyboard on an ASCII terminal or the keyboard and hand icon on a graphical display), press the F5 key on the directly attached keyboard or the number 5 key on an ASCII terminal.
6.If the Console Selection screen is displayed, choose the system console.
7.Enter the appropriate password if you are prompted to do so.
Is the "Please define the System Console" screen displayed?
NO Either the last external device that you connected or the system board is probably defective.
To test each FRU, exchange the FRUs in the following order:
1.If the failure is related to an external device that you are responsible for servicing, follow the service procedures for that device.
Otherwise, contact the vendor (or have the customer contact the vendor) to have the device serviced.
2.System board (see note 3 on page
| Repeat this step until all the listed devices are connected. |
YES | Repeat this step until all the listed devices are connected. |
| Go to “Step |
Chapter 2. Maintenance Analysis Procedures (MAPs) |