| Error Code | Function | Repair Action/Possible Failing FRU | 
| 
 | /Description | 
 | 
| 
 | 
 | 
 | 
| 25A80xxx | NVRAM problem | Notes: | 
| 
 | 
 | 1. Errors reported against NVRAM can be caused by | 
| 
 | 
 | low battery voltage and (more rarely) power | 
| 
 | 
 | outages that occur during normal system usage. | 
| 
 | 
 | With the exception of the 25A80000 error, these | 
| 
 | 
 | errors are really just warnings that the NVRAM | 
| 
 | 
 | data content had to be  | 
| 
 | 
 | require any FRU replacement unless the error is | 
| 
 | 
 | persistent. When one of these errors occurs, any | 
| 
 | 
 | system customization (for example boot device list) | 
| 
 | 
 | information has been lost. The system may need | 
| 
 | 
 | to be reconfigured. | 
| 
 | 
 | 2. If the error is persistent, replace the battery. | 
| 
 | 
 | 3. If the error is persistent after battery replacement, | 
| 
 | 
 | or the error code is 25A80000, replace the system | 
| 
 | 
 | board (see note 3 on page  | 
| 
 | 
 | 
 | 
| 25A80000 | Initialization failed, | Refer to 25A80xxx. | 
| 
 | device test failed. | 
 | 
| 
 | 
 | 
 | 
| 25A80001 | Refer to 25A80xxx. | |
| 
 | ALL of NVRAM | 
 | 
| 
 | initialized. | 
 | 
| 
 | 
 | 
 | 
| 25A80002 | Refer to 25A80xxx. | |
| 
 | some data partitions | 
 | 
| 
 | may have been | 
 | 
| 
 | preserved. | 
 | 
| 
 | 
 | 
 | 
| 25A80011 | Data corruption | Refer to 25A80xxx. | 
| 
 | detected, ALL of | 
 | 
| 
 | NVRAM initialized. | 
 | 
| 
 | 
 | 
 | 
| 25A80012 | Data corruption | Refer to 25A80xxx. | 
| 
 | detected, some data | 
 | 
| 
 | partitions may have | 
 | 
| 
 | been preserved. | 
 | 
| 
 | 
 | 
 | 
| 25A80100 | NVRAM data | Turn off, then turn on the server and retry the | 
| 
 | validation check | operation before replacing any system components. | 
| 
 | failed. | Refer to 25A80xxx. | 
| 
 | 
 | |
| 
 | 
 | 
 | 
| 25A80201 | Unable to expand | Refer to 25A80xxx. | 
| 
 | target partition while | 
 | 
| 
 | saving configuration | 
 | 
| 
 | variable. | 
 | 
| 
 | 
 | 
 | 
| 25A80202 | Unable to expand | Refer to 25A80xxx. | 
| 
 | target partition while | 
 | 
| 
 | writing error log | 
 | 
| 
 | entry. | 
 | 
| 
 | 
 | 
 | 
| Chapter 3. Error Code to FRU Index | 