IBM B50 Error Code, Function, Repair Action/Possible Failing FRU, Description, NVRAM problem

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 71
Image 71

Error Code

Function

Repair Action/Possible Failing FRU

 

/Description

 

 

 

 

25A80xxx

NVRAM problem

Notes:

 

 

1. Errors reported against NVRAM can be caused by

 

 

low battery voltage and (more rarely) power

 

 

outages that occur during normal system usage.

 

 

With the exception of the 25A80000 error, these

 

 

errors are really just warnings that the NVRAM

 

 

data content had to be re-established and do not

 

 

require any FRU replacement unless the error is

 

 

persistent. When one of these errors occurs, any

 

 

system customization (for example boot device list)

 

 

information has been lost. The system may need

 

 

to be reconfigured.

 

 

2. If the error is persistent, replace the battery.

 

 

3. If the error is persistent after battery replacement,

 

 

or the error code is 25A80000, replace the system

 

 

board (see note 3 on page 2-1).

 

 

 

25A80000

Initialization failed,

Refer to 25A80xxx.

 

device test failed.

 

 

 

 

25A80001

init-nvram invoked,

Refer to 25A80xxx.

 

ALL of NVRAM

 

 

initialized.

 

 

 

 

25A80002

init-nvram invoked,

Refer to 25A80xxx.

 

some data partitions

 

 

may have been

 

 

preserved.

 

 

 

 

25A80011

Data corruption

Refer to 25A80xxx.

 

detected, ALL of

 

 

NVRAM initialized.

 

 

 

 

25A80012

Data corruption

Refer to 25A80xxx.

 

detected, some data

 

 

partitions may have

 

 

been preserved.

 

 

 

 

25A80100

NVRAM data

Turn off, then turn on the server and retry the

 

validation check

operation before replacing any system components.

 

failed.

Refer to 25A80xxx.

 

 

 

 

 

25A80201

Unable to expand

Refer to 25A80xxx.

 

target partition while

 

 

saving configuration

 

 

variable.

 

 

 

 

25A80202

Unable to expand

Refer to 25A80xxx.

 

target partition while

 

 

writing error log

 

 

entry.

 

 

 

 

Chapter 3. Error Code to FRU Index