Error Code | Function | Repair Action/Possible Failing FRU |
| /Description |
|
|
|
|
25A80xxx | NVRAM problem | Notes: |
|
| 1. Errors reported against NVRAM can be caused by |
|
| low battery voltage and (more rarely) power |
|
| outages that occur during normal system usage. |
|
| With the exception of the 25A80000 error, these |
|
| errors are really just warnings that the NVRAM |
|
| data content had to be |
|
| require any FRU replacement unless the error is |
|
| persistent. When one of these errors occurs, any |
|
| system customization (for example boot device list) |
|
| information has been lost. The system may need |
|
| to be reconfigured. |
|
| 2. If the error is persistent, replace the battery. |
|
| 3. If the error is persistent after battery replacement, |
|
| or the error code is 25A80000, replace the system |
|
| board (see note 3 on page |
|
|
|
25A80000 | Initialization failed, | Refer to 25A80xxx. |
| device test failed. |
|
|
|
|
25A80001 | Refer to 25A80xxx. | |
| ALL of NVRAM |
|
| initialized. |
|
|
|
|
25A80002 | Refer to 25A80xxx. | |
| some data partitions |
|
| may have been |
|
| preserved. |
|
|
|
|
25A80011 | Data corruption | Refer to 25A80xxx. |
| detected, ALL of |
|
| NVRAM initialized. |
|
|
|
|
25A80012 | Data corruption | Refer to 25A80xxx. |
| detected, some data |
|
| partitions may have |
|
| been preserved. |
|
|
|
|
25A80100 | NVRAM data | Turn off, then turn on the server and retry the |
| validation check | operation before replacing any system components. |
| failed. | Refer to 25A80xxx. |
|
| |
|
|
|
25A80201 | Unable to expand | Refer to 25A80xxx. |
| target partition while |
|
| saving configuration |
|
| variable. |
|
|
|
|
25A80202 | Unable to expand | Refer to 25A80xxx. |
| target partition while |
|
| writing error log |
|
| entry. |
|
|
|
|
Chapter 3. Error Code to FRU Index |