IBM B50 Error Code, Function, Repair Action/Possible Failing FRU, Description, Unknown or, device

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 66
Image 66
Unknown or

Error Code

Function

Repair Action/Possible Failing FRU

 

 

/Description

 

 

 

 

 

 

20A80002

Cannot get gateway

Refer to “Firmware Checkpoints” on page

3-14,using

 

IP address.

code E174.

 

 

 

 

 

20A80003

Cannot get server

Refer to “Firmware Checkpoints” on page

3-14,using

 

hardware address

code E174.

 

 

 

 

 

20A80004

Bootp failed

Refer to “Firmware Checkpoints” on page

3-14,using

 

 

code E174.

 

 

 

 

 

20A80005

File transmission

Check network connection and try again.

 

 

(TFTP) failed

 

 

 

 

 

 

20A80006

Boot image too

Verify boot server configuration.

 

 

large. Ran out of

 

 

 

available firmware

 

 

 

memory resources

 

 

 

loading boot image.

 

 

20D00xxx

Unknown or

 

 

Unrecognized

 

 

device

 

 

 

 

20D0000F

Self-test failed on

Check the SMS error log entry for this error code. The

 

device, no

location code (if present) in the error log entry should

 

error/location code

identify the location of the failing device.

 

information

 

 

available.

 

 

 

 

20D00010

Self-test failed on

Software Error (Contact your service representative for

 

device, cannot

assistance.)

 

locate package

 

 

 

 

20D00011

Cannot determine

The Machine Model is part of the System Vital Product

 

Machine Model.

Data. Perform corrective actions listed for errors

 

 

2BA00050, 2BA00051.

20E00xxx

Security

 

20E00000

Power-on password

The password has been entered incorrectly.

 

entry error.

Retry installing the password.

 

 

 

 

 

20E00001

Privileged-access

The password has been entered incorrectly.

 

password entry

Retry installing the password.

 

error.

 

 

 

 

 

20E00002

Privileged-access

The privileged-access password jumper is not in the

 

password jumper

correct position for password initial entry.

 

not enabled.

Consult the server User's Guide for pin location and

 

 

 

 

jumper position.

 

 

 

20E00003

Power-on password

Unattended mode requires setting the Power-on

 

must be set for

password before it is enabled.

 

Unattended mode.

 

 

 

 

20E00004

Battery drained or

1. Replace battery

 

needs replacement.

2. Replace system board (see note 3 on page 2-1).