Error Code

Function

Repair Action/Possible Failing FRU

 

 

 

/Description

 

 

 

 

 

 

 

 

25AA0xxx

EEPROM problem

Notes:

 

 

 

 

1. Ensure that the EEPROM Security jumper is in the

 

 

correct position if doing a privileged-access

 

 

password installation.

 

 

 

 

2. Retry the operation.

 

 

 

 

3. If retries do not solve the problem, replace the

 

 

system board (see note 3 on page 2-1).

 

 

 

 

 

 

25AA0000

Unable to unlock

Refer to 25AA0xxx.

 

 

 

EEPROM

 

 

 

 

 

 

 

 

25AA0001

Read-Recv error

Refer to 25AA0xxx.

 

 

 

 

 

 

 

25AA0002

Read-Trans error

Refer to 25AA0xxx.

 

 

 

 

 

 

 

25AA0003

Write-enable error

Refer to 25AA0xxx.

 

 

 

 

 

 

 

25AA0004

Write-recv error

Refer to 25AA0xxx.

 

 

 

 

 

 

 

25AA0005

Write-disable error

Refer to 25AA0xxx.

 

 

 

 

 

 

 

25AA0006

Write-Trans error

Refer to 25AA0xxx.

 

 

 

 

 

 

 

25AA0007

Unable to lock

Refer to 25AA0xxx.

 

 

 

EEPROM

 

 

 

 

 

 

25Cyyxxx

Memory errors

Use the location code obtained from the SMS Error

 

 

Log utility (described in “Step 1020-3” on page

2-8)to

 

 

identify which memory dimm the error is reported

 

 

against.

 

 

 

 

Memory error codes are in the form25Cyyxxx

where

 

 

yy indicates memory dimm PD-bits and

xxx

indicates

 

 

the last three digits of the error code.

 

 

 

 

See “Memory PD Bits” on page 3-13 for information on

 

 

how to interpret PD bits.

 

 

 

 

 

 

 

25Cyy002

Memory dimm failed

1. Replace memory dimm

 

 

 

memory test

2. Replace system board (see note 3 on page 2-1).

 

 

See “Memory PD Bits” on page 3-13 for

 

 

 

 

information on how to interpret PD bits.

 

 

 

 

 

 

Chapter 3. Error Code to FRU Index

3-9

Page 73
Image 73