Symptom

Symptom

 

Action

 

 

The system stops and POST indicators are

Go to “MAP 1540: Minimum Configuration” on

displayed on the system console. The term

page 2-17.to isolate the problem.

"POST indicators" refer to the icons (graphic

 

display) or device mnemonics (ASCII terminal)

 

that appear during the power-on self-test

 

(POST).

 

 

 

 

The system stops and the message "STARTING

Go to “Firmware Checkpoints” on page 3-14.

SOFTWARE PLEASE WAIT..." is displayed on

 

the ASCII terminal, or the boot indicator

 

(

) is displayed on a graphics terminal.

 

 

 

The system does not respond to the password

Verify that the password is being entered from a

being entered, or the system login prompt is

keyboard or ASCII terminal defined as the

displayed when booting in service mode.

system console. If so, then the keyboard or its

 

 

controller may be faulty.

 

 

If the password is being entered from a

 

 

keyboard attached to the system, replace

 

 

the keyboard. If that does not fix the

 

 

problem, replace the system board (see

 

 

note 3 on page 2-1).

 

 

If the password is being entered from an

 

 

ASCII terminal, use the Problem

 

 

Determination Procedures for the ASCII

 

 

terminal. Make sure the ASCII terminal is

 

 

connected to Serial Port 1. Replace the

 

 

system board if these procedures do not

 

 

reveal a problem (see note 3 on page 2-1).

 

 

No codes are displayed on the operator panel

Reseat the operator panel cable. If the problem

within a few seconds of turning on the system.

is not resolved, replace these parts in the

The operator panel is blank before the system is

following order:

powered on.

1. Operator Panel Assembly. Update the VPD

 

 

 

 

information in the new operator panel.

 

 

2. System board (see note 3 on page 2-1).

 

 

The power LED on the operator panel comes on

Automatic power-up is a feature on the Model

and the system powers on automatically when

B50. Refer to the System Board Jumper

A/C power is applied.

Settings in Chapter 1 for the correct settings. If

 

 

the jumper is set in the disabled position,

 

 

replace the system board (see note 3 on page

 

 

2-1).

 

 

The SMS configuration list or Boot sequence

A device may be set to use the same SCSI bus

selection menu shows more SCSI devices

ID as the control adapter. Note the ID being

attached to a controller/adapter than are actually

used by the controller/adapter (this can be

attached.

 

checked and/or changed via an SMS utility), and

 

 

verify that no device attached to the controller is

 

 

set to use that ID. If settings do not appear to

 

 

be in conflict, go to “Boot Problems or

 

 

Concerns” on page 3-27.

 

 

 