Checkpoint

Description

Repair Action

(hex)

 

 

 

 

 

 

 

E602

SSA PCI adapter

1.

Replace the adapter.

 

open firmware has

2.

See “Unresolved problems” on page 3-26

 

started.

 

 

 

 

 

 

E603

SSA PCI adapter

1.

Replace the adapter.

 

BIST has completed

2.

See “Unresolved problems” on page 3-26

 

with an error.

 

 

 

 

 

 

E604

SSA PCI adapter

1.

Replace the adapter.

 

BIST and

2.

See “Unresolved problems” on page 3-26

 

subsequent POSTs

 

 

 

have completed

 

 

 

successfully.

 

 

 

 

 

 

E605

SSA PCI adapter

1.

Replace the adapter.

 

BIST has completed

2.

See “Unresolved problems” on page 3-26

 

successfully but the

 

 

 

subsequent POSTs

 

 

 

have failed.

 

 

 

 

 

 

E60E

SSA PCI adapter

1.

Replace the adapter.

 

open firmware about

2.

See “Unresolved problems” on page 3-26

 

to exit (no stack

 

 

 

corruption)

 

 

 

 

 

 

E60F

SSA PCI adapter

1.

Replace the adapter.

 

open firmware has

2.

See “Unresolved problems” on page 3-26

 

run unsuccessfully.

 

 

 

 

 

 

E6FF

SSA PCI adapter

1.

Replace the adapter.

 

open firmware about

2.

See “Unresolved problems” on page 3-26

 

to exit ( with stack

 

 

 

corruption ).

 

 

 

 

 

 

Unresolved problems:Go to “MAP 1540: Minimum Configuration” on page

2-17for any of the following conditions:

A 4-digit code in the range of “E100” through “EFFF” is displayed on the operator panel display but is not listed in the table that lists firmware checkpoints on page 3-14.

A 4-digit code is displayed and is listed in the table that lists firmware

checkpoints on page 3-14,but there are no repair actions or FRUs listed for the code.

All of the FRUs listed in repair actions have been replaced, and the problem has not been corrected.

3-267046 Model B50 Service Guide

Page 90
Image 90
IBM B50 manual E6FF