| Error Code | Function | Repair | Action/Possible Failing FRU | 
| 
 | /Description | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
| 20E00005 | EEPROM locked. | 1. | Turn off, then turn on the server. | 
| 
 | 
 | 2. Replace system board (see note 3 on page  | |
| 
 | 
 | 
 | |
| 20E00008 | CMOS corrupted or | Check your machine for evidence of tampering. | |
| 
 | tampering evident, | If NO tampering: | |
| 
 | CMOS initialized. | ||
| 
 | 1. | Replace battery, restore NVRAM data (passwords, | |
| 
 | 
 | ||
| 
 | 
 | 
 | startup data). | 
| 
 | 
 | 2. Replace system board (see note 3 on page  | |
| 
 | 
 | 
 | |
| 20E00009 | Invalid password | The password has been entered incorrectly 3 times. | |
| 
 | entered - system | Turn off, then turn on the server, then enter the | |
| 
 | locked. | ||
| 
 | password correctly. | ||
| 
 | 
 | ||
| 
 | 
 | 
 | |
| 20E0000A | EEPROM lock | If for  | |
| 
 | problem. | correct position? | |
| 
 | 
 | Consult the server User's Guide for pin location and | |
| 
 | 
 | jumper position. | |
| 
 | 
 | 1. | Turn off, then turn on the server. | 
| 
 | 
 | 2. Replace system board (see note 3 on page  | |
| 
 | 
 | 
 | 
 | 
| 20E0000B | EEPROM write | 1. | Turn off, then turn on the server. | 
| 
 | problem. | 2. Replace system board (see note 3 on page  | |
| 
 | 
 | 
 | 
 | 
| 20E0000C | EEPROM read | 1. | Turn off, then turn on the server. | 
| 
 | problem. | 2. Replace system board (see note 3 on page  | |
| 
 | 
 | 
 | |
| 20E00017 | Cold boot needed | Turn off, then turn on the server. | |
| 
 | for password entry. | 
 | 
 | 
| 20EE0xxx | Informational | 
 | 
| 20EE0003 | IP parameter | Enter valid IP parameter | 
| 
 | requires 3 dots "." | Example: 000.000.000.000 | 
| 
 | 
 | |
| 
 | 
 | 
 | 
| 20EE0004 | Invalid IP parameter. | Enter valid (numeric) IP parameter | 
| 
 | 
 | Example: 000.000.000.000 | 
| 
 | 
 | 
 | 
| 20EE0005 | Invalid IP parameter | Enter valid (numeric) IP parameter in the range of 0 to | 
| 
 | (>255). | 255 | 
| 
 | 
 | Example: 255.199.002.000 | 
| 
 | 
 | 
 | 
| 20EE0006 | No SCSI controllers | The system board should always have at least 2 | 
| 
 | present. | integrated PCI SCSI controllers. Replace the system | 
| 
 | 
 | board (see note 3 on page  | 
| 
 | 
 | 
 | 
| 20EE0007 | Keyboard not found. | 1. Plug in keyboard | 
| 
 | 
 | 2. Replace system board (see note 3 on page  | 
| 
 | 
 | 
 | 
| 20EE0008 | No configurable | This warning occurs when the selected SMS function | 
| 
 | adapters found in | cannot locate any devices/adapters supported by the | 
| 
 | the system. | function. If a supported device is installed: | 
| 
 | 
 | 1. Replace the device or adapter. | 
| 
 | 
 | 2. Replace system board (see note 3 on page  | 
| Chapter 3. Error Code to FRU Index | 