IBM B50 Error Code, Function, Action/Possible Failing FRU, Description, Informational, Repair

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 67
Image 67
Repair

Error Code

Function

Repair

Action/Possible Failing FRU

 

/Description

 

 

 

 

 

 

20E00005

EEPROM locked.

1.

Turn off, then turn on the server.

 

 

2. Replace system board (see note 3 on page 2-1).

 

 

 

20E00008

CMOS corrupted or

Check your machine for evidence of tampering.

 

tampering evident,

If NO tampering:

 

CMOS initialized.

 

1.

Replace battery, restore NVRAM data (passwords,

 

 

 

 

 

startup data).

 

 

2. Replace system board (see note 3 on page 2-1).

 

 

 

20E00009

Invalid password

The password has been entered incorrectly 3 times.

 

entered - system

Turn off, then turn on the server, then enter the

 

locked.

 

password correctly.

 

 

 

 

 

20E0000A

EEPROM lock

If for privileged-access password install, is jumper in

 

problem.

correct position?

 

 

Consult the server User's Guide for pin location and

 

 

jumper position.

 

 

1.

Turn off, then turn on the server.

 

 

2. Replace system board (see note 3 on page 2-1).

 

 

 

 

20E0000B

EEPROM write

1.

Turn off, then turn on the server.

 

problem.

2. Replace system board (see note 3 on page 2-1).

 

 

 

 

20E0000C

EEPROM read

1.

Turn off, then turn on the server.

 

problem.

2. Replace system board (see note 3 on page 2-1).

 

 

 

20E00017

Cold boot needed

Turn off, then turn on the server.

 

for password entry.

 

 

20EE0xxx

Informational

 

20EE0003

IP parameter

Enter valid IP parameter

 

requires 3 dots "."

Example: 000.000.000.000

 

 

 

 

 

20EE0004

Invalid IP parameter.

Enter valid (numeric) IP parameter

 

 

Example: 000.000.000.000

 

 

 

20EE0005

Invalid IP parameter

Enter valid (numeric) IP parameter in the range of 0 to

 

(>255).

255

 

 

Example: 255.199.002.000

 

 

 

20EE0006

No SCSI controllers

The system board should always have at least 2

 

present.

integrated PCI SCSI controllers. Replace the system

 

 

board (see note 3 on page 2-1).

 

 

 

20EE0007

Keyboard not found.

1. Plug in keyboard

 

 

2. Replace system board (see note 3 on page 2-1).

 

 

 

20EE0008

No configurable

This warning occurs when the selected SMS function

 

adapters found in

cannot locate any devices/adapters supported by the

 

the system.

function. If a supported device is installed:

 

 

1. Replace the device or adapter.

 

 

2. Replace system board (see note 3 on page 2-1).