IBM B50 Error Code, Function, Repair Action/Possible Failing FRU, Description, Memory Controller

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 70
Image 70

Error Code

Function

Repair Action/Possible Failing FRU

 

/Description

 

 

 

 

25000xxx

Memory Controller

 

 

problem

 

 

 

 

25000000

Memory controller

Replace system board (see note 3 on page 2-1).

 

failed

 

 

 

 

25010xxx

Flash Update

 

 

problem

 

 

 

 

25010000

No diskette in drive.

Insert diskette containing firmware update file.

 

 

 

25010001

Diskette seek error.

1. Retry function.

 

 

2. Replace diskette drive.

 

 

3. Replace diskette cable.

 

 

4. Replace system board (see note 3 on page 2-1).

 

 

 

25010002

Diskette in drive

Insert diskette with firmware update file

 

does not contain an

 

 

*.IMG file.

 

 

 

 

25010003

Cannot open

Replace system board (see note 3 on page 2-1).

 

OPENPROM

 

 

package.

 

 

 

 

25010004

Cannot find

Replace system board (see note 3 on page 2-1).

 

OPENPROM node.

 

 

 

 

25010006

System ID does not

Make sure correct firmware update diskette is being

 

match image system

used with this system.

 

ID.

 

 

 

 

25010007

Image has bad

Replace firmware update diskette.

 

CRC.

 

 

 

 

25010008

Flash is write

1. Turn off, then turn on the server and retry.

 

protected, update

2. Replace system board (see note 3 on page 2-1).

 

cancelled.

 

 

 

 

25010009

Flash module is

Make sure correct firmware update diskette is being

 

unsupported or not

used with this system.

 

recognized.

 

 

 

 

2501000A

Flash write

1. Turn off, then turn on the server and retry.

 

protected.

2. Replace system board (see note 3 on page 2-1).

 

 

 

3-67046 Model B50 Service Guide

Page 70
Image 70