Error Code | Function | Repair Action/Possible Failing FRU |
| /Description |
|
|
|
|
25000xxx | Memory Controller |
|
| problem |
|
|
|
|
25000000 | Memory controller | Replace system board (see note 3 on page |
| failed |
|
|
|
|
25010xxx | Flash Update |
|
| problem |
|
|
|
|
25010000 | No diskette in drive. | Insert diskette containing firmware update file. |
|
|
|
25010001 | Diskette seek error. | 1. Retry function. |
|
| 2. Replace diskette drive. |
|
| 3. Replace diskette cable. |
|
| 4. Replace system board (see note 3 on page |
|
|
|
25010002 | Diskette in drive | Insert diskette with firmware update file |
| does not contain an |
|
| *.IMG file. |
|
|
|
|
25010003 | Cannot open | Replace system board (see note 3 on page |
| OPENPROM |
|
| package. |
|
|
|
|
25010004 | Cannot find | Replace system board (see note 3 on page |
| OPENPROM node. |
|
|
|
|
25010006 | System ID does not | Make sure correct firmware update diskette is being |
| match image system | used with this system. |
| ID. |
|
|
|
|
25010007 | Image has bad | Replace firmware update diskette. |
| CRC. |
|
|
|
|
25010008 | Flash is write | 1. Turn off, then turn on the server and retry. |
| protected, update | 2. Replace system board (see note 3 on page |
| cancelled. |
|
|
|
|
25010009 | Flash module is | Make sure correct firmware update diskette is being |
| unsupported or not | used with this system. |
| recognized. |
|
|
|
|
2501000A | Flash write | 1. Turn off, then turn on the server and retry. |
| protected. | 2. Replace system board (see note 3 on page |
|
|
|