If the symptom did not change and all the FRUs have been exchanged, call your service support person for assistance.
If the symptom has changed, check for loose cards, cables, and obvious problems. If you do not find a problem, return to “Step 1540-1” on page 2-18, and follow the instructions for the new symptom.
The last device or cable that you disconnected is defective. Exchange the defective device or cable.
Repeat this step until the defective device or cable is identified or all the devices and cables have been disconnected.
If all the devices and cables have been removed, then one of the FRUs remaining in the server is defective.
To test each FRU, exchange the FRUs in the following order:
Step 1540-13
1.Make sure the diagnostic
2.Turn off the power.
3.Starting with the
4.Turn on the power.
5.If the Console Selection screen is displayed, choose the system console.
6.After the keyboard indicator begins blinking, press the F5 key on the directly attached keyboard or the number 5 key on an ASCII terminal keyboard.
7.Enter the appropriate password if you are prompted to do so.
Is the "Please define the System Console" screen displayed?
NO
1.Adapter (last one installed)
2.Riser card
3.System board (see note 3 on page
4.Power supply
YES
Go to "MAP 0410: Repair Checkout | " in theDiagnostics Information for |
Multiple Bus Systems. |
|