IBM B50 manual 2-21, Step, Does the operator panel do one of the following, Stop with any code

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 51
Image 51
2-21

Step 1540-5

No failure was detected with this configuration.

1.Turn off the power.

2.Install a memory module.

3.Turn on the power.

Does the operator panel do one of the following:

￿ Stop with any code

other than E1DC, E1F2, E1F3, E1F7 or E14D?

￿Alternate between E1FD and any other code?

NO

Repeat this step until all the memory modules are installed and tested.

 

After all the memory modules are installed and tested, go to “Step

 

1540-8” on page 2-22.

YES

Go to “Step 1540-6”

Step 1540-6

The failure may be caused by the last memory module installed. To isolate the failing FRU, do the following:

1.Turn off the power.

2.Exchange the last memory module installed.

3.Turn on the power.

Does the operator panel do one of the following:

￿ Stop with any code

other than E1DC, E1F2, E1F3, E1F7 or E14D?

￿Alternate between E1FD and any other code?

NO

Go to "MAP 0410: Repair Checkout

" in theDiagnostics Information for

 

Multiple Bus Systems.

 

YES

Go to “Step 1540-7” on page 2-22.

 

Chapter 2. Maintenance Analysis Procedures (MAPs)

2-21

Page 51
Image 51
IBM B50 2-21, Step, Does the operator panel do one of the following, Stop with any code, in theDiagnostics Information for