Step 1540-5
No failure was detected with this configuration.
1.Turn off the power.
2.Install a memory module.
3.Turn on the power.
Does the operator panel do one of the following:
Stop with any code | other than E1DC, E1F2, E1F3, E1F7 or E14D? |
Alternate between E1FD and any other code?
NO | Repeat this step until all the memory modules are installed and tested. |
| After all the memory modules are installed and tested, go to “Step |
| |
YES | Go to “Step |
Step 1540-6
The failure may be caused by the last memory module installed. To isolate the failing FRU, do the following:
1.Turn off the power.
2.Exchange the last memory module installed.
3.Turn on the power.
Does the operator panel do one of the following:
Stop with any code | other than E1DC, E1F2, E1F3, E1F7 or E14D? |
Alternate between E1FD and any other code?
NO | Go to "MAP 0410: Repair Checkout | " in theDiagnostics Information for |
| Multiple Bus Systems. |
|
YES | Go to “Step |
|
Chapter 2. Maintenance Analysis Procedures (MAPs) |