MAP 1240: Memory Problem Resolution
Note: The firmware checkpoint that sent you here could be one of the following:
E122, E213, E214, E218, E220 or E3xx
Each of these checkpoints is referred to as a memory checkpoint in this MAP.
Purpose of this MAP
This MAP is used to troubleshoot a problem during the memory test when the system stops at a memory checkpoint and no error code is displayed on the system console.
General Memory Information
Be sure to unplug the power cable before removing or installing the memory modules to avoid damage to them.
The memory modules do not need to be installed in pairs and can be installed in any slot on the system board. There is no requirement that one slot be installed before the other.
Refer to “Memory Modules” on page
Note: If the symptom changes while using this MAP, check for loose cards, cables, and obvious problems. If you do not find a problem, go to “MAP 1540: Minimum Configuration” on page