| Error Code | Function | Repair Action/Possible Failing FRU | 
| 
 | /Description | 
 | 
| 
 | 
 | 
 | 
| 25A80203 | Unable to expand | Refer to 25A80xxx. | 
| 
 | target partition while | 
 | 
| 
 | writing VPD data. | 
 | 
| 
 | 
 | 
 | 
| 25A80210 | Setenv/$Setenv | Refer to 25A80xxx. | 
| 
 | parameter error - | 
 | 
| 
 | name contains a null | 
 | 
| 
 | character. | 
 | 
| 
 | 
 | 
 | 
| 25A80211 | Setenv/$Setenv | Refer to 25A80xxx. | 
| 
 | parameter error - | 
 | 
| 
 | value contains a null | 
 | 
| 
 | character. | 
 | 
| 
 | 
 | 
 | 
| 25A80998 | NVRAMRC script | Execution of a command line within the nvram | 
| 
 | evaluation error - | configuration variable “nvramrc” (script) resulted in a | 
| 
 | command line | “throw” being executed. This script can be modified by | 
| 
 | execution error | the system firmware SMS utilities, the operating | 
| 
 | 
 | system, PCI adapter rom code or utility, or an operator | 
| 
 | 
 | (via the open firmware script editing command nvedit ). | 
| 
 | 
 | It may not be possible to resolve the problem without a | 
| 
 | 
 | detailed analysis of the nvram script, the current | 
| 
 | 
 | system configuration, and device tree contents. | 
| 
 | 
 | 1. The problem can be caused by a SCSI | 
| 
 | 
 | adapter,whose SCSI bus ID has been changed | 
| 
 | 
 | from the default setting, no longer appearing in the | 
| 
 | 
 | system. This can be caused either by removing a | 
| 
 | 
 | SCSI adapter, or a problem with a SCSI adapter. | 
| 
 | 
 | a. Select the SCSI ID utility from the SMS | 
| 
 | 
 | menu(s). | 
| 
 | 
 | 1) Verify the list of SCSI controllers/adapters. | 
| 
 | 
 | If the list is not correct, suspect a problem | 
| 
 | 
 | with the adapter(s) installed but not listed. | 
| 
 | 
 | 2) Select the option to save the configuration | 
| 
 | 
 | information. | 
| 
 | 
 | 3) Restart the system. | 
| 
 | 
 | b. If the problem persists, boot the operating | 
| 
 | 
 | system and verify the SCSI bus IDs of any | 
| 
 | 
 | installed/available SCSI controllers (change as | 
| 
 | 
 | necessary), and restart the system. | 
| 
 | 
 | 2. Contact your service support representative for | 
| 
 | 
 | further assistance. | 
| 
 | 
 | 
 | 
| 25A80999 | NVRAMRC script | This is a firmware debug environment error. There is | 
| 
 | evaluation error - | no user action or FRU replacement for this error. | 
| 
 | stack unbalanced on | 
 | 
| 
 | completion. | 
 | 
| 
 | 
 | 
 | 