IBM B50 manual 3-25, Checkpoint, Description, Repair Action

Models: B50

1 198
Download 198 pages 21.09 Kb
Page 89
Image 89

Checkpoint

Description

Repair Action

(hex)

 

 

 

 

 

E244

Enable system

Replace system board (see note 3 on page 2-1).

 

speaker and send a

 

 

beep

 

 

 

 

E246

System firmware

Replace system board (see note 3 on page 2-1).

 

corrupted, take

 

 

recover path

 

 

 

 

E247

Capture DIMM

Replace system board (see note 3 on page 2-1).

 

SPDs into NVRAM

 

 

 

 

E249

Enter recover path's

Replace system board (see note 3 on page 2-1).

 

main code

 

 

 

 

E24C

L2 cache array test

Replace system board (see note 3 on page 2-1).

 

fails. System hangs.

 

 

 

 

E24D

L2 cache array test

Replace system board (see note 3 on page 2-1).

 

fails. System

 

 

hangs.

 

 

 

 

E298

Take firmware

Replace Softload Image

 

soft-load path

 

 

 

 

E299

Start C code

See “Unresolved problems” on page 3-26

 

execution.

 

 

 

 

E3xx

Memory test

See “MAP 1240: Memory Problem Resolution” on

 

 

page 2-9

 

 

 

E440

Validate nvram,

1. Verify that the system firmware is at the current

 

initialize partitions as

release level. Update as necessary.

 

needed

2. See “Unresolved problems” on page 3-26

 

 

 

E441

Generate /options

1. Verify that the system firmware is at the current

 

node nvram

release level. Update as necessary.

 

configuration

2. See “Unresolved problems” on page 3-26

 

variable properties

 

 

 

 

E442

Validate nvram

1. Verify that the system firmware is at the current

 

partitions

release level. Update as necessary.

 

 

2. See “Unresolved problems” on page 3-26

 

 

 

E443

Generate nvram

1. Suspect a system firmware problem. If problem

 

configuration

persists, verify that the system firmware is at

 

variable dictionary

current release level. Update downlevel system

 

words

firmware.

 

 

2. See “Unresolved problems” on page 3-26

 

 

 

E600

SSA PCI adapter

1. Replace the adapter.

 

open firmware has

2. See “Unresolved problems” on page 3-26

 

run successfully.

 

 

 

 

E601

SSA PCI adapter

1. Replace the adapter.

 

BIST has been

2. See “Unresolved problems” on page 3-26

 

started but failed to

 

 

complete after 4

 

 

seconds.

 

 

 

 

Chapter 3. Error Code to FRU Index

3-25

Page 89
Image 89
IBM B50 manual 3-25, Checkpoint, Description, Repair Action