Checkpoint

Description

Repair Action

(hex)

 

 

 

 

 

E122

No memory

1. Replace memory dimm(s)

 

detected (system

2. Replace System Planar

 

lockup) Note:

3. Replace System Planar

 

Harddisk light is on

See “Unresolved problems” on page 3-26

 

continuously

 

 

 

 

 

E123

No SIMM found in

See “Unresolved problems” on page 3-26

 

the socket

 

 

 

 

E124

Disable defective

See “Unresolved problems” on page 3-26

 

memory bank

 

 

 

 

E125

Clear PCI devices

See “Unresolved problems” on page 3-26

 

command reg, go

 

 

forth

 

 

 

 

E126

Check valid image -

See “Unresolved problems” on page 3-26

 

start

 

 

 

 

E127

Check valid image -

See “Unresolved problems” on page 3-26

 

successful

 

 

 

 

E128

Disable interrupts,

See “Unresolved problems” on page 3-26

 

set int vectors for

 

 

O.F.

 

 

 

 

E129

Validate target RAM

See “Unresolved problems” on page 3-26

 

address

 

 

 

 

E12A

Copy ROM to RAM,

See “Unresolved problems” on page 3-26

 

flush cache

 

 

 

 

E12B

Set MP operational

See “Unresolved problems” on page 3-26

 

parameters (eg.

 

 

L.E.?, Real?)

 

 

 

 

E12C

Set MP CPU node

See “Unresolved problems” on page 3-26

 

characteristics

 

 

 

 

E12D

Park secondary

See “Unresolved problems” on page 3-26

 

processors in

 

 

parking lot

 

 

 

 

E12E

Primary processor

See “Unresolved problems” on page 3-26

 

sync

 

 

 

 

E12F

Unexpected return

See “Unresolved problems” on page 3-26

 

from Open Firmware

 

 

(system lockup)

 

 

 

 

E130

Build device tree

See “Unresolved problems” on page 3-26

 

 

 

E131

Create ROOT node

See “Unresolved problems” on page 3-26

 

 

 

E132

Create CPUs node

See “Unresolved problems” on page 3-26

 

 

 

3-167046 Model B50 Service Guide

Page 80
Image 80
IBM B50 manual Checkpoint Description Repair Action Hex