Step 1540-4

One of the FRUs remaining in the server is defective.

1.Turn off the power.

2.Exchange one of the FRUs in the following list: System board (see note 3 on page 2-1). Memory module

3.Turn on the power.

Note: You are asked questions regarding the operator panel display. You are also asked to perform certain actions based on displayed POST indicators. Please be observant of these conditions.

Does the operator panel do one of the following:

￿ Stop with any code

other than E1DC, E1F2, E1F3, E1F7 or E14D?

￿Alternate between E1FD and any other code?

NO

Go to "MAP 0410: Repair Checkout

" in theDiagnostics Information for

 

Multiple Bus Systems.

 

YES

Reinstall the original FRU.

 

 

Repeat the FRU replacement steps until the defective FRU is identified or

 

all the FRUs have been exchanged.

 

If the symptom did not change and all the FRUs have been exchanged, call your service support person for assistance.

If the symptom has changed, check for loose cards, cables, and obvious problems. If you do not find a problem, return to “Step 1540-1”on page 2-18,and follow the instructions for the new symptom.