Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-57

F-57

 

 

TROUBLESHOOTING & REPAIR

AUXILIARY TRANSFORMER NO. 2 REMOVAL AND

REPLACEMENT PROCEDURE (CONTINUED)

REPLACEMENT PROCEDURE

1.Carefully place the transformer into the Power Wave 455/R.

2.Install the two mounting screws that hold the transformer to the machine base using the 3/8” nut driver.

3.Connect leads 33 and 32 to circuit breaker CB4 and the 115 V receptacle.

4.Connect plugs P50 and P52.

5.Reposition any wire leads and install cable ties as necessary.

6.Install the case back using the 3/8” nut driver.

7.Install the case top, sides, and input access panel using the 3/8” nut driver.

POWER WAVE 455/R

Page 103
Image 103
Lincoln Electric SVM156-A service manual Replacement Procedure