TOC
TOC
OPERATION
CASE FRONT CONTROLS
Return to Section
Return to Section TOC
TOC
Return to Master
Return to Master TOC
TOC
All operator controls and adjustments are located on the case front of the Power Wave. (See Figure B.1)
1.POWER SWITCH: Controls input power to the Power Wave.
2.STATUS LIGHT: A two color light that indicates sys- tem errors. Normal operation is a steady green light. Error conditions are indicated, per Table B.1.
NOTE: The robotic Power Waves’ status light will flash green, and sometimes red and green, for up to one minute when the machine is first turned on. This is a normal situation as the machine goes through a self test at power up.
| TABLE B.1 | |
Light | Meaning | |
Condition | ||
| ||
|
| |
Steady | System OK. Power source | |
Green | communicating normally with | |
| wire feeder and its components. | |
|
| |
Blinking | Normal for first | |
Green | after power is turned on. | |
|
| |
Alternating | ||
Green | Must turn power source off, find | |
and Red | source of error, and turn power | |
| back on to reset. See | |
| Troubleshooting Guide. | |
|
| |
Steady | See Troubleshooting Guide. | |
Red |
|
3.HIGH TEMPERATURE LIGHT (thermal overload): A yellow light that comes on when an over tem- perature situation occurs. Output is disabled until the machine cools down. When cool, the light goes out and output is enabled.
4.10 AMP WIRE FEEDER CIRCUIT BREAKER: Protects 40 volt DC wire feeder power supply.
5.10 AMP AUXILIARY POWER CIRCUIT BREAKER: Protects 115 volt AC case front receptacle auxil- iary supply.
6.LEAD CONNECTOR S2 (SENSE LEAD)
7.
8.
9.I / O CONNECTOR
10.NEGATIVE OUTPUT TERMINAL
11.INTERFACE CONNECTOR S6
12.STT TERMINAL
13.POSITIVE OUTPUT TERMINAL
14.AUXILIARY OUTPUT
Return to Section
Return to Master
FIGURE B.1 – POWER WAVE CASE FRONT CONTROLS
2 3
to Section TOC
to Master TOC
6
7
8
9
10
POWERWAVE 455/R
ION
O OFF
1
11
12
13
Return
Return
5 14 4