Lincoln Electric SVM156-A service manual Case Front Controls, Table B.1

Models: SVM156-A

1 150
Download 150 pages 63.85 Kb
Page 24
Image 24

TOC

TOC

B-6

B-6

OPERATION

CASE FRONT CONTROLS

Return to Section

Return to Section TOC

TOC

Return to Master

Return to Master TOC

TOC

All operator controls and adjustments are located on the case front of the Power Wave. (See Figure B.1)

1.POWER SWITCH: Controls input power to the Power Wave.

2.STATUS LIGHT: A two color light that indicates sys- tem errors. Normal operation is a steady green light. Error conditions are indicated, per Table B.1.

NOTE: The robotic Power Waves’ status light will flash green, and sometimes red and green, for up to one minute when the machine is first turned on. This is a normal situation as the machine goes through a self test at power up.

 

TABLE B.1

Light

Meaning

Condition

 

 

 

Steady

System OK. Power source

Green

communicating normally with

 

wire feeder and its components.

 

 

Blinking

Normal for first 1-10 seconds

Green

after power is turned on.

 

 

Alternating

Non-recoverable system fault.

Green

Must turn power source off, find

and Red

source of error, and turn power

 

back on to reset. See

 

Troubleshooting Guide.

 

 

Steady

See Troubleshooting Guide.

Red

 

3.HIGH TEMPERATURE LIGHT (thermal overload): A yellow light that comes on when an over tem- perature situation occurs. Output is disabled until the machine cools down. When cool, the light goes out and output is enabled.

4.10 AMP WIRE FEEDER CIRCUIT BREAKER: Protects 40 volt DC wire feeder power supply.

5.10 AMP AUXILIARY POWER CIRCUIT BREAKER: Protects 115 volt AC case front receptacle auxil- iary supply.

6.LEAD CONNECTOR S2 (SENSE LEAD)

7.5-PIN ARC LINK S1

8.5-PIN DEVICENET CONNECTOR S5

9.I / O CONNECTOR

10.NEGATIVE OUTPUT TERMINAL

11.INTERFACE CONNECTOR S6

12.STT TERMINAL

13.POSITIVE OUTPUT TERMINAL

14.AUXILIARY OUTPUT

Return to Section

Return to Master

FIGURE B.1 – POWER WAVE CASE FRONT CONTROLS

2 3

to Section TOC

to Master TOC

6

7

8

9

10

POWERWAVE 455/R

ION

O OFF

1

11

12

13

Return

Return

5 14 4

POWER WAVE 455/R

Page 24
Image 24
Lincoln Electric SVM156-A service manual Case Front Controls, Table B.1