Lincoln Electric SVM156-A service manual Receptacle

Models: SVM156-A

1 150
Download 150 pages 63.85 Kb
Page 85
Image 85

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-39

F-39

 

TROUBLESHOOTING & REPAIR

STT CURRENT TRANSDUCER TEST (CONTINUED)

FIGURE F.14 – RECEPTACLE S7 TRIGGERED

 

 

RECEPTACLE

STT

WAVE

S7

POWER

 

Return to Section TOC

Return to Master TOC

5.Turn on the Power Wave 455/R. Check for the correct DC supply voltage to the current transducer at plug J8.

A.Pin 8 (lead 812+) to pin 7 (lead 816-) should read +15 VDC.

B.Pin 4 (lead 813-) to pin 7 (lead 816+) should read -15 VDC.

If the DC supply voltages are not present, the control board may be faulty.

6.If both of the supply voltages are low or missing, check the associated leads between plug J8 and current transducer plug P90 and the Control Board.

NOTE: The machine can be triggered by jumpering pin 1 to pin 2 at receptacle S7. See Figure F. 14.

7.With the Power Wave 455/R triggered, check the feedback voltage from the current transducer. The current feedback voltage can be read at plug J8 on the Control Board.

A.Pin 5 (lead 811) to pin 7 (lead 816) should read 2.0 VDC (machine loaded to 50 amps).

Return to Section TOC

Return to Master TOC

POWER WAVE 455/R

Page 85
Image 85
Lincoln Electric SVM156-A service manual Receptacle