AUXILIARY TRANSFORMER NO. 1 TEST (CONTINUED)

TABLE F.7 – SECONDARY VOLTAGES

LEAD IDENTIFICATION

NORMAL EXPECTED VOLTAGE

 

 

X1 to X2

52 VAC

X3 to X5

115 VAC

X3 to X4

24 VAC

 

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

7.Carefully apply the correct input voltage to the Power Wave 455/R.

WARNING

ELECTRIC SHOCK can kill.

High voltage is present at prima- ry of the Auxiliary Transformer.

8.Check for the correct secondary voltages according to Table F.7.

NOTE: The secondary voltages will vary if the input line voltage varies.

9.If the correct secondary voltages are pre- sent, the T1 auxiliary transformer is func- tioning properly. If any of the secondary voltages are missing or low, check to make certain the primary is configured correctly for the input voltage applied. See the Wiring Diagram.

10.If the correct input voltage is applied to the primary, and the secondary voltage(s) are not correct, the T1 transformer may be faulty.

11.Replace any cables ties and insulation removed earlier.

12.Install the case sides and top using the 3/8” nut driver.