F-29

F-29

 

 

TROUBLESHOOTING & REPAIR

INPUT BOARD TEST(CONTINUED)

TABLE F.5 – INPUT BOARD VOLTAGE CHECKS

 

 

 

LEAD

 

EXPECTED

 

TEST POINTS

 

NUMBERS

 

VOLTAGE

COMMENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J61 PIN 8 (H1D)

 

 

J61

 

SAME AS

Present when Input

TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

Switch SW1 is closed.

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J61 PIN 2 (612)

#612

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H1D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J61 PIN 10 (T3)

 

 

J61

 

A LITTLE LESS

This is Pre-Charge Voltage and

TO

 

T1

 

THAN INPUT

will normally be present 6 sec-

PLUG J61 PIN 2 (T1)

 

 

VOLTAGE

onds after activating Input Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1. The Pre-Charge Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

should remain for approximately 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds and then be removed.

 

 

 

 

 

 

 

 

 

 

 

 

 

T3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J60 PIN 3 (238)

 

 

J60

 

13 – 15 VDC

This is the Coil Voltage for the

TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre-Charge Relay. Normally this

PLUG J60 PIN 4 (604)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Voltage will be present 6 sec-

 

#238 #604

 

 

onds after Input Switch SW1 is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

activated. This 13 - 15 VDC will

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

remain for approximately 6 sec-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

onds and then be removed. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay is controlled by the Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Board. See the Wiring Diagram.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J60 PIN 3 (238)

 

J60

 

13 – 15 VDC

This is the DC Coil Voltage for the

TO

 

 

 

 

Control Relay. Normally this DC

PLUG J60 PIN 5 (232)

 

 

 

 

Voltage will be present approxi-

 

 

 

#238

mately 12 seconds after Input

 

 

 

Switch SW1 is activated. The

 

 

 

 

 

 

 

 

 

 

Relay is controlled by the Control

 

 

 

 

 

 

 

 

 

 

PC Board. See the Wiring

 

 

 

 

 

Diagram.

 

#232

 

 

 

 

POWER WAVE 455/R