Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-29

F-29

 

 

TROUBLESHOOTING & REPAIR

INPUT BOARD TEST(CONTINUED)

TABLE F.5 – INPUT BOARD VOLTAGE CHECKS

 

 

 

LEAD

 

EXPECTED

 

TEST POINTS

 

NUMBERS

 

VOLTAGE

COMMENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J61 PIN 8 (H1D)

 

 

J61

 

SAME AS

Present when Input

TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

Switch SW1 is closed.

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J61 PIN 2 (612)

#612

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H1D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J61 PIN 10 (T3)

 

 

J61

 

A LITTLE LESS

This is Pre-Charge Voltage and

TO

 

T1

 

THAN INPUT

will normally be present 6 sec-

PLUG J61 PIN 2 (T1)

 

 

VOLTAGE

onds after activating Input Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW1. The Pre-Charge Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

should remain for approximately 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds and then be removed.

 

 

 

 

 

 

 

 

 

 

 

 

 

T3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J60 PIN 3 (238)

 

 

J60

 

13 – 15 VDC

This is the Coil Voltage for the

TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre-Charge Relay. Normally this

PLUG J60 PIN 4 (604)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Voltage will be present 6 sec-

 

#238 #604

 

 

onds after Input Switch SW1 is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

activated. This 13 - 15 VDC will

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

remain for approximately 6 sec-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

onds and then be removed. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay is controlled by the Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Board. See the Wiring Diagram.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG J60 PIN 3 (238)

 

J60

 

13 – 15 VDC

This is the DC Coil Voltage for the

TO

 

 

 

 

Control Relay. Normally this DC

PLUG J60 PIN 5 (232)

 

 

 

 

Voltage will be present approxi-

 

 

 

#238

mately 12 seconds after Input

 

 

 

Switch SW1 is activated. The

 

 

 

 

 

 

 

 

 

 

Relay is controlled by the Control

 

 

 

 

 

 

 

 

 

 

PC Board. See the Wiring

 

 

 

 

 

Diagram.

 

#232

 

 

 

 

POWER WAVE 455/R

Page 75
Image 75
Lincoln Electric SVM156-A service manual Comments