TROUBLESHOOTING & REPAIR

SWITCH BOARD TEST (CONTINUED)

FIGURE F.3 – SWITCH BOARD TEST POINTS

 

 

 

13/14

 

 

 

OR

 

 

 

17/18

 

SWITCH

 

 

 

BOARD

 

-20 +19

 

11/12

 

 

 

 

 

OR

 

 

 

15/16

 

 

8. Reconnect leads 19C and 19D to the recon- 9.

Install the right and left case sides and top

nect switches. Ensure that the leads are

using the 3/8” nut driver.

installed in the same location they were

 

 

removed from.

 

 

 

TABLE F.1 – SWITCH BOARD RESISTANCE TEST

APPLY POSITIVE TEST

APPLY NEGATIVE TEST

RESISTANCE READING

PROBE TO TERMINAL

NORMAL

 

 

 

PROBE TO TERMINAL

 

+19

11/12 OR 15/16

Greater than 1000 ohms

+19

13/14 OR 17/18

Greater than 1000 ohms

11/12 OR 15/16

- 20

 

Greater than 1000 ohms

13/14 OR 17/18

- 20

 

Greater than 1000 ohms

- 20

11/12 OR 15/16

Less than 100 ohms

- 20

13/14 OR 17/18

Less than 100 ohms

11/12 OR 15/16

+19

 

Less than 100 ohms

13/14 OR 17/18

+19

 

Less than 100 ohms