Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-13

F-13

 

 

TROUBLESHOOTING & REPAIR

SWITCH BOARD TEST (CONTINUED)

FIGURE F.3 – SWITCH BOARD TEST POINTS

 

 

 

13/14

 

 

 

OR

 

 

 

17/18

 

SWITCH

 

 

 

BOARD

 

-20 +19

 

11/12

 

 

 

 

 

OR

 

 

 

15/16

 

 

8. Reconnect leads 19C and 19D to the recon- 9.

Install the right and left case sides and top

nect switches. Ensure that the leads are

using the 3/8” nut driver.

installed in the same location they were

 

 

removed from.

 

 

 

TABLE F.1 – SWITCH BOARD RESISTANCE TEST

APPLY POSITIVE TEST

APPLY NEGATIVE TEST

RESISTANCE READING

PROBE TO TERMINAL

NORMAL

 

 

 

PROBE TO TERMINAL

 

+19

11/12 OR 15/16

Greater than 1000 ohms

+19

13/14 OR 17/18

Greater than 1000 ohms

11/12 OR 15/16

- 20

 

Greater than 1000 ohms

13/14 OR 17/18

- 20

 

Greater than 1000 ohms

- 20

11/12 OR 15/16

Less than 100 ohms

- 20

13/14 OR 17/18

Less than 100 ohms

11/12 OR 15/16

+19

 

Less than 100 ohms

13/14 OR 17/18

+19

 

Less than 100 ohms

POWER WAVE 455/R

Page 59
Image 59
Lincoln Electric SVM156-A service manual Figure F.3 Switch Board Test Points