Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
|
| TROUBLESHOOTING & REPAIR |
SWITCH BOARD TEST (CONTINUED)
FIGURE F.3 – SWITCH BOARD TEST POINTS
|
|
| 13/14 |
|
|
| OR |
|
|
| 17/18 |
| SWITCH |
|
|
| BOARD |
| |
| 11/12 |
| |
|
|
| |
| OR |
|
|
| 15/16 |
|
|
8. Reconnect leads 19C and 19D to the recon- 9. | Install the right and left case sides and top | ||
nect switches. Ensure that the leads are | using the 3/8” nut driver. | ||
installed in the same location they were |
|
| |
removed from. |
|
|
|
TABLE F.1 – SWITCH BOARD RESISTANCE TEST | |||
APPLY POSITIVE TEST | APPLY NEGATIVE TEST | RESISTANCE READING | |
PROBE TO TERMINAL | NORMAL |
|
|
| PROBE TO TERMINAL |
| |
+19 | 11/12 OR 15/16 | Greater than 1000 ohms | |
+19 | 13/14 OR 17/18 | Greater than 1000 ohms | |
11/12 OR 15/16 | - 20 |
| Greater than 1000 ohms |
13/14 OR 17/18 | - 20 |
| Greater than 1000 ohms |
- 20 | 11/12 OR 15/16 | Less than 100 ohms | |
- 20 | 13/14 OR 17/18 | Less than 100 ohms | |
11/12 OR 15/16 | +19 |
| Less than 100 ohms |
13/14 OR 17/18 | +19 |
| Less than 100 ohms |