Lincoln Electric SVM156-A service manual Figure F.19 Input Contactor Removal and Replacement

Models: SVM156-A

1 150
Download 150 pages 63.85 Kb
Page 97
Image 97

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-51

F-51

 

 

TROUBLESHOOTING & REPAIR

INPUT CONTACTOR REMOVAL AND REPLACEMENT (CONTINUED)

FIGURE F.19 – INPUT CONTACTOR REMOVAL AND REPLACEMENT

INPUT

CONTACTOR

601

X4

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

REMOVAL PROCEDURE

1.Remove input power to the Power Wave 455/R.

2.Using the 3/8” nut driver, remove the case top, sides, and input access panel.

3.Perform the Capacitor Discharge proce- dure

4.Locate the input contactor. Label and, using the phillips head screwdriver, careful- ly remove the leads from the input contac- tor terminals. Note placement for reassem- bly. See Figure F.19.

5.With the 5/16” nut driver, remove the three mounting screws. See Figure F.19.

6.Carefully remove the input contactor.

REPLACEMENT PROCEDURE

1.Mount the contactor and tighten the mount- ing screws.

2.Assemble the leads to the correct terminals. See Figure F.18.

3.Install the case top, sides, and input access panel using the 3/8” nut driver.

POWER WAVE 455/R

Page 97
Image 97
Lincoln Electric SVM156-A service manual Figure F.19 Input Contactor Removal and Replacement