to Section TOC

to Master TOC

F-36

F-36

 

 

TROUBLESHOOTING & REPAIR

POWER WAVE CURRENT TRANSDUCER TEST (CONTINUED)

Return

Return

8.If for any reason the machine cannot be loaded to 250 amps, Table F.6 shows what feedback voltage is produced at various cur- rent loads.

9.If the correct supply voltages are applied to the current transducer, and with the machine loaded, the feedback voltage is missing or

not correct, the current transducer may be faulty. Also make certain that lead 211 (plug J8 pin 1) has continuity (zero ohms) between the current transducer and the control board. See the Wiring Diagram.

10.Install the right side case cover using the 3/8” nut driver.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

TABLE F.6 - CURRENT FEEDBACK AT VARIOUS OUTPUT LOADS

OUTPUT LOAD CURRENT

EXPECTED TRANSDUCER FEEDBACK

 

VOLTAGE

 

 

 

500

4.0

 

450

3.6

 

400

3.2

 

350

2.8

 

300

2.4

 

250

2.0

 

200

1.6

 

150

1.2

 

100

0.8

 

50

0.4

 

 

 

 

POWER WAVE 455/R

Page 82
Image 82
Lincoln Electric SVM156-A service manual 500 450 400 350 300 250 200 150 100