Lincoln Electric SVM156-A service manual Troubleshooting Guide, Output Problems

Models: SVM156-A

1 150
Download 150 pages 63.85 Kb
Page 50
Image 50

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-4

 

 

 

F-4

TROUBLESHOOTING & REPAIR

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

Major physical or electrical damage

Contact

your local authorized

Contact the Lincoln Electric Service

is evident when the sheet metal

Lincoln

Electric Field Service

Department at 1-800-833-9353

covers are removed.

Facility for technical assistance.

(WELD).

 

 

 

 

The input fuses repeatedly fail or

1. Make certain the fuses or break-

1. Check the reconnect switches

the input circuit breakers keep trip-

ers are properly sized.

 

and associated wiring. See the

ping.

2. Make certain the reconnect

 

Wiring Diagram.

 

 

 

 

 

panel is configured properly for

2. Perform the Input Rectifier

 

the applied voltage.

 

Test.

 

3. The welding procedure may be

3.

Perform the Switch Board Test.

 

drawing too much input current

4.

Perform the Input Contactor

 

or the duty cycle may be too

 

 

Test.

 

high. Reduce the welding cur-

 

 

 

 

 

 

rent and /or reduce the duty

 

 

 

 

cycle.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

POWER WAVE 455/R

Page 50
Image 50
Lincoln Electric SVM156-A service manual Troubleshooting Guide, Output Problems