TROUBLESHOOTING & REPAIR

STT CURRENT TRANSDUCER

REMOVAL AND PLACEMENT (CONTINUED)

FIGURE F.25 – STT CURRENT TRANSDUCER REMOVAL AND REPLACEMENT PROCEDURE

RESISTOR

ASSEMBLY

1 2 3 4

P90

STT OUTPUT

 

TERMINAL

CURRENT

(TOP RIGHT)

TRANSDUCER

 

REMOVAL PROCEDURE

1.

Remove input power to the Power Wave

5. Label and remove the leads to the resistor

 

455/R.

assembly. See Figure F.25.

Using the

2.

Using the 3/8” nut driver, remove the case

5/16” socket wrench, extension and univer-

sal adapter, remove the resistor assembly.

 

top and right side.

 

It may be necessary to remove the glastic

 

 

3.

Perform the Capacitor Discharge proce-

high voltage protection shield.

(Use the

 

dure.

3/8” nut driver.) It may also be necessary to

4.

Using the wire cutters, cut all cable ties to

use a 5/16” open end wrench to remove the

inside screws. Carefully swing the resistor

 

 

the transducer lead harness. Unplug the

assembly aside.

harness and swing it aside.

 