TROUBLESHOOTING & REPAIR

INPUT BOARD TEST (CONTINUED)

FIGURE F.9 – INPUT CONTACTOR CR1

Return to Section TOC

Return to Master TOC

J60

J61

1

2

3

4

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

6

7

8

6

7

8

9 10

 

J60

 

 

 

J61

 

601

X4

INPUT CONTACTOR

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Remove input power to the Power Wave 455/R.

2.Using the 3/8” nut driver, remove the case top.

3.Remove lead X4 from the coil terminal of main input contactor CR1. Insulate lead X4. Refer to Figure F.9.

4.Carefully apply input power to the Power Wave 455/R.

WARNING

ELECTRIC SHOCK can kill.

High voltage is present when input power is applied to the machine.

5.Turn on the Power Wave 455/R. Carefully test for the correct voltages according to

Table F.5.

POWER WAVE 455/R

Page 73
Image 73
Lincoln Electric SVM156-A service manual Table F.5