| TROUBLESHOOTING & REPAIR |
POWER WAVE CURRENT TRANSDUCER
REMOVAL AND REPLACEMENT
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call
TEST DESCRIPTION
This procedure will aid the technician in the removal and replacement of the Power Wave Current Transducer.
MATERIALS NEEDED
3/8” Nut driver
5/16” Open end wrench 9/16” Wrench
3/4” Wrench
Phillips head screw driver Wire cutters
Wiring Diagram
This procedure should take approximately 25 minutes to perform.