F-44

F-44

 

 

TROUBLESHOOTING & REPAIR

AUXILIARY TRANSFORMER NO. 1 TEST (CONTINUED)

FIGURE F.16 – AUXILIARY TRANSFORMER NO. 1 TEST

X3 X5

 

 

FAN MOTOR

X1

+

LEADS

INPUT

CONTACTOR

601

X4

Return to Section TOC

Return to Master TOC

- X2

POWER BOARD RECTIFIER BRIDGE

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Remove the main input power to the Power Wave 455/R machine.

2.Using the 3/8” nut driver, remove the case top and sides.

3.Perform the Capacitor Discharge proce- dure.

4.Locate secondary leads X1 and X2 (at power board rectifier bridge). Refer to Figure F.16.

5.Locate secondary leads X3 and X5 (fan motor leads).

6.Locate secondary lead X4 (at main contac- tor).