TROUBLESHOOTING & REPAIR

POWER BOARD TEST (CONTINUED)

FIGURE F.8 – POWER BOARD TEST

J42

J41

J43

1

2

3

1

2

1

2

3

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

6

3

4

7

8

9 10 11 12

 

J42

 

J41

 

 

J43

TEST PROCEDURE

Return to Section

Return to Master

1.Remove input power to the Power Wave 455/R.

2.Using the 3/8” nut driver, remove the case top.

3.Perform the Capacitor Discharge Procedure.

4.Locate the Power Board and plugs J42 and J43. Do not remove plugs or leads from the Power Board. Refer to Figure F.8.

5.Carefully apply input power to the Power Wave 455/R.

6.Turn on the Power Wave 455/R. Carefully test for the correct voltages at the Power Board according to Table F.4.

7.If either of the 40 VDC voltages is low or not present at plug J41, perform the DC Bus PC Board Test. See the Wiring Diagram. Also perform the T1 Auxiliary Transformer Test.

8.If any of the DC voltages are low or not pre- sent at plugs J42 and/or 43, the Power Board may be faulty.

9.Install the case top using the 3/8” nut driver.

Return to Section TOC

Return to Master TOC

WARNING

ELECTRIC SHOCK can kill.

High voltage is present when input power is applied to the machine.

POWER WAVE 455/R

Page 70
Image 70
Lincoln Electric SVM156-A service manual Figure F.8 Power Board Test