TROUBLESHOOTING & REPAIR

AUXILIARY TRANSFORMER NO. 2 REMOVAL AND

REPLACEMENT PROCEDURE (CONTINUED)

FIGURE F.21 – AUXILIARY TRANSFORMER NO. 2 REMOVAL AND REPLACEMENT

INPUT

CONTACTOR

601

X4

P52

P50

CB4 CIRCUIT

BREAKER &

115V RECEPTACLE LEADS 33/32

Return to Section TOC

Return to Master TOC

REMOVAL PROCEDURE

1.Remove input power to the Power Wave 455/R.

2.Using the 3/8” nut driver, remove the case top, sides and input access panel.

3.Perform the Capacitor Discharge proce- dure.

4.Using the 3/8” nut driver, remove the case back.

5.Disconnect plugs P50 and P52.

6.Disconnect leads 33 and 32 to circuit breaker CB2 and the 115 V receptacle.

7.Using the 3/8” nut driver, remove the two transformer mounting screws.

POWER WAVE 455/R

Page 102
Image 102
Lincoln Electric SVM156-A service manual CB4 Circuit Breaker 115V Receptacle Leads 33/32