GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches

2.In the Ping field, select either Global or Link Global to select either the global IPv6 Address or host name or link local address to ping.

3.Optionally, configure the following settings:

In the IPv6 Address/Host Name field, enter the IPv6 address or host name of the station you want the switch to ping. The initial value is blank. The IPv6 address or host name you enter is not retained across a power cycle. The valid range is 0–160 characters.

In the Datagram Size field, enter the datagram size. The valid range is 48–2048.

The Result field displays the result after the switch sends a ping IPv6 request to the specified IPv6 address.

4.Click APPLY to send the ping.

The switch sends the number of pings specified in the Count field, and the results are displayed in the Results field.

If a reply to the ping is received, you see “Send count=3, Receive count = n from (IPv6 Address).Average round-trip time = n ms.”

If a reply to the ping is not received, you see “Reply From IP/Host: Destination Unreachable. Tx = x, Rx = 0 Min/Max/Avg RTT = 0/0/0 msec”.

Traceroute

Use the Traceroute utility to discover the paths that a packet takes to a remote destination.

240

Page 240
Image 240
NETGEAR GS752TP, GS728TPP manual Traceroute