a force-authorized state and does not require any authentication. When the Port Control setting is Auto, the authenticator PAE sets the controlled port mode.

3.In the Guest VLAN field for ports g1–g8, enter 150 to assign these ports to the guest VLAN.

You can configure more settings to control access to the network through the ports. See Port Security Interface Configuration for information about the settings.

4.Click APPLY.

5.In the 802.1x Configuration screen, set the port-based authentication state and guest VLAN mode to Enable and click APPLY.

For more information, see Port Security Interface Configuration on page 184.

This example uses the default values for the port authentication settings, but you can configure several more settings. For example, the EAPOL Flood Mode field allows you to enable the forwarding of EAPoL frames when 802.1x is disabled on the device.

6.In the RADIUS Server Configuration screen, configure a RADIUS server with the following settings:

Server Address. 192.168.10.23

Secret Configured. Yes

Secret. secret123

Active. Primary

For more information, see Configure RADIUS Settings on page 159.

7.Click Add.

8.In the Authentication List screen, configure the default list to use RADIUS as the first authentication method.

For more information, see Authentication List Configuration on page 165.

This example enables 802.1x-based port security on the switch and prompts the hosts connected on ports g1–g8 for an 802.1x-based authentication. The switch passes the authentication information to the configured RADIUS server.