GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches

To configure the Traceroute settings and send probe packets to discover the route to a host on the network:

1.Select Maintenance > Troubleshooting > Traceroute. The following screen displays:

2.In the IP Address/Hostname field, specify the IP address or the host name of the station you want the switch to ping.

The initial value is blank. This information is not retained across a power cycle.

3.Optionally, configure the following settings:

Probes Per Hop. Specify the number of times each hop must be probed. The valid range is 1–10.

MaxTTL. Specify the maximum time-to-live for a packet in number of hops. The valid range is 1–255.

InitTTL. Specify the initial time-to-live for a packet in number of hops. The valid range is 1–255.

MaxFail. Specify the maximum number of failures allowed in the session. The valid range is 0–255.

Interval. Specify the time between probes in seconds. The valid range is 1–60.

Port. Specify the UDP destination port in probe packets. The valid range is 1–65535.

Size. Specify the size of probe packets. The valid range is 64–1472.

4.Click APPLY to initiate the traceroute. The results display in the Results field.

241

Page 241
Image 241
NETGEAR GS728TPP, GS752TP manual 241