164
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
2. In the Key String field, specify the authentication and encryption key for TACACS+
communications between the switch and the TACACS+ server.
The valid range is 0–128 characters. The key must match the key configured on the
TACACS+ server.
3. In the Connection Timeout field, specify the maximum number of seconds allowed to
establish a TCP connection between the switch and the TACACS+ server.
The valid range is 1–30 seconds.
4. Click APPLY to update the switch with the RADIUS Accounting server settings.
TACACS+ Server Configuration
Use the TACACS+ Server Configuration screen to configure up to five TACACS+ servers
with which the switch can communicate.
To configure TACACS+ server settings:
1. Select Security Management Security > TACACS+ TACACS+ Server Configuration
link.
The following screen displays:
2. In the TACACS+ Server field, enter the IP address of the server to add
3. In the Priority field, specify the order in which the TACACS+ servers are used.
A value of 0 is the highest priority.
4. In the Port field, specify the authentication port number through which the TACACS+
session occurs.
The default is port 49, and the range is 0–65535.