NETGEAR WFS709TP-100NAS manual Master-Local WFS709TP Redundancy, Vrrp Associations

Models: WFS709TP-100NAS

1 222
Download 222 pages 54.79 Kb
Page 153
Image 153

WFS709TP ProSafe Smart Wireless Switch Software Administration Manual

3.

Enter the parameters shown in Table 11-1. For this topology, the following values are

 

recommended:

 

 

 

 

• Priority: Set the “initially preferred” master to 110 and set the backup master to 100.

 

• Enable pre-emption.

 

 

 

 

• Configure master up time or master state tracking with an add value of 20.

4.

Configure the values in the respective fields, then click Done to enter the values.

5.

Click Apply to apply the configuration and add the VRRP instance.

6.

Associate the VRRP instance with the master WFS709TP redundancy (see Table 11-2).

 

Table 11-2. VRRP Associations

 

 

 

 

 

 

 

 

Association

Function

Switch ID

 

 

 

 

 

 

 

Master VRRP

Associates a VRRP instance with

Virtual Router ID of the VRRP

 

 

 

master redundancy

instance

 

 

 

 

 

 

 

Peer’s IP Address

Loopback IP address of the peer

Loopback IP address of the peer

 

 

 

for master redundancy

WFS709TP

 

7.

 

 

 

 

Configure the APs to terminate their tunnels on the Virtual IP address. See “Configuring APs”

 

on page 10-3.

 

 

 

Note: All the APs and local WFS709TPs in the network should be configured with the VIP address as the master IP address.

The master IP address is configured for local WFS709TPs during the initial setup of the switch. You can also change the master IP address configured on the local WFS709TP in the Configuration > Advanced > Switch > General page in the browser interface.

The WFS709TP requires a reboot after you change the master IP of the WFS709TP.

If Domain Name Service (DNS) resolution is the chosen mechanism for the APs to discover their master WFS709TP, ensure that the name “netgear-master” resolves to the same VIP address configured as a part of the master redundancy.

Master-Local WFS709TP Redundancy

This section outlines the concepts behind a redundancy solution where a master can act as a backup for one or more local WFS709TPs, and shows how to configure the WFS709TPs for such a redundant solution. In this solution, the local WFS709TPs act as the switches for the APs. When

Configuring Redundancy

11-5

v1.0, June 2007

Page 153
Image 153
NETGEAR WFS709TP-100NAS manual Master-Local WFS709TP Redundancy, Vrrp Associations, Association Function Switch ID