Paradyne 7112 manual Testing3 state, IfInOctets ifEntry, IfInErrors ifEntry

Models: 7112

1 156
Download 156 pages 11.03 Kb
Page 108
Image 108

MIB Descriptions

Table C-2. Interfaces Group Objects (4 of 5)

Object

Description

Setting/Contents

 

 

 

ifOperStatus

Specifies the current

H Ethernet port

(ifEntry 8)

operational state of the

± up(1) ± No alarms

1.3.6.1.2.1.2.2.1.8

interface. Read/Write

± down(2) ± Alarms

 

 

 

 

± testing(3) ± Test active

 

 

H Terminal port. Always up(1); never

 

 

in testing(3) state.

 

 

H User Data Port

 

 

± up(1) ± No alarms

 

 

± down(2) ± Alarms

 

 

± testing(3) ± Test active

 

 

H DS1 Network Interface

 

 

± up(1) ± DTR on, if supported by

 

 

the DTE

 

 

± down(2) ± DTR off, if supported

 

 

by the DTE

 

 

± testing(3) ± Test active

 

 

H Facility Data Link (FDL). When

 

 

enabled, up and down are based

 

 

on the current state of the physical

 

 

and link layer protocols.

 

 

± up(1) ± Operational and no

 

 

active test on the DS1 network

 

 

interface

 

 

± down(2) ± Not operational or

 

 

disabled

 

 

± testing(3) ± Test active on DS1

 

 

network interface

 

 

 

ifLastChange

Indicates the amount

Contains the value of sysUpTime

(ifEntry 9)

of time the interface

object at the time the interface

1.3.6.1.2.1.2.2.1.9

has been up and

entered its current operational state.

 

running.

 

 

 

 

ifInOctets (ifEntry 10)

Collects input statistics

An integer number.

1.3.6.1.2.1.2.2.1.10

on data received by

 

 

the interface.

 

ifInUcastPkts

 

 

 

(ifEntry 11)

 

 

1.3.6.1.2.1.2.2.1.11

Applies to the FDL and

 

 

 

 

the Ethernet port.

 

ifInDiscards

 

Statistics are not

 

(ifEntry 13)

 

collected if the

 

1.3.6.1.2.1.2.2.1.13

 

Ethernet port is

 

 

 

ifInErrors (ifEntry 14)

disabled.

 

 

 

1.3.6.1.2.1.2.2.1.14

 

 

 

 

 

ifInUnknown

 

 

Protos

 

 

(ifEntry 15)

 

 

1.3.6.1.2.1.2.2.1.15

 

 

 

 

 

C-6

March 1998

7112-A2-GB20-10

Page 108
Image 108
Paradyne 7112 manual Testing3 state, IfInOctets ifEntry, IfInErrors ifEntry