Security

If entering yes to prompt . . .

Then . . .

 

 

Reset COM Port usage

H Port Type is set to Terminal

 

H Data Rate (kbps) is set to 9.6

 

H Character Length is set to 8

 

H Stop Bits is set to 1

 

H Parity is set to None

 

H External Device Commands is set to Disable

 

 

Reload Factory Defaults

All factory-loaded configuration and control

 

settings contained in the Default Factory

 

Configuration configuration area are loaded.

 

 

If no (or n) is entered, or if no selection is made within 30 seconds, the access unit returns to the condition or operation it was in when the system reset was initiated, with the COM port rate returning to its configured rate.

The access unit resets itself, going through a Device Self-Test. Connectivity is restored and the Main Menu screen appears.

ATI Access

Access to the ATI is available through either the Terminal port or a Telnet session.

Access to the ATI through the Terminal port can be limited. Refer to Table A-6,

Terminal Port Options, to:

HEnable Login Required.

HAssign a Port Access Level of 1, 2, or 3.

The ATI can be accessed remotely through a Telnet Session via either the Ethernet port or the FDL. The DSU/CSU provides several methods for limiting access to the ATI through a Telnet session.

HRefer to Table A-7,Telnet Session Options, to:

ÐEnable Login Required.

ÐAssign a Telnet Session Access Level of 1, 2, or 3.

ÐDisable Telnet access completely.

HTo prevent the 10BaseT port and FDL from supporting a Telnet session:

ÐSet the Ethernet Port Use option to Disable. Refer to Table A-5,Ethernet Port Options.

ÐDisable the FDL. Refer to Table A-2, Network Interface Options.

NOTE:

Preventing access to the ATI by setting the FDL or Ethernet Port Use options to Disable also inhibits SNMP management over those interfaces.

4-4

March 1998

7112-A2-GB20-20

Page 32
Image 32
Paradyne 7112 manual ATI Access, If entering yes to prompt Then