Paradyne 7112 manual Table A-9. Snmp NMS Security Options 2, Access Level

Models: 7112

1 156
Download 156 pages 11.03 Kb
Page 94
Image 94

Configuration Option Tables

Table A-9. SNMP NMS Security Options (2 of 2)

NMS n IP Address

Possible Settings: 000.000.000.000 ± 255.255.255.255, Clear

Default Setting: 000.000.000.000

Enter an IP address for each of the managers set in the previous option. n is the number of the manager (1 to 10). Use the next option to establish the security level for each SNMP manager.

NOTE: When an SNMP message is received from an IP address that does not match the IP address entries in this option, access is denied and an ªauthenticationFailureº trap is generated.

000.000.000.000 ± 255.255.255.255 ± Sets the NMS IP address. The range for the first byte is 001 to 255, with the exception of 127. The range for the remaining three bytes is 000 to 255.

Clear ± Clears the IP address and sets to all zeros.

Access Level

Possible Settings: Read, Read/Write

Default Setting: Read

Set the access level for each IP address created in the previous option.

Read ± Allows a read-only access (SNMP Get) to accessible MIB objects.

Read/Write ± Allows both an SNMP Get and Set to MIB objects. Write access allowed to all MIB objects specified as read-write in the MIB RFC. This access level is overridden by the Community Name's access level for the SNMP Manager, if the Community Name access level is Read.

A-18

March 1998

7112-A2-GB20-10

Page 94
Image 94
Paradyne 7112 manual Table A-9. Snmp NMS Security Options 2, Access Level