Configuring the DSU/CSU

Using the Individual Channel Assignment Method

This channel method allows you to select the individual DS0 channels to allocate to the data port. The data port rate is automatically determined based on the number of channels selected. The DS0s do not need to be contiguous.

"Procedure

To assign the data port by the individual channel method:

1.Access the Cross Connect Assignments screen by following this menu selection sequence:

Main Menu Configuration Load Configuration From

Cross Connect

2.Use the Assign By field to specify the assignment method (Channel).

3.Specify the port assignments for the individual DS0 channels. The DS0 channels do not need to be contiguous.

4.The port rate increases as the port is assigned to each additional DS0 channel. For example, if two DS0 channels (at 64 kbps each) are assigned to the data port, a port rate of 128 kbps is required.

5.Select Ctrl-a and then Save to save your changes.

Clearing DS0 Channel Assignments

You can clear (deallocate) all the DS0 channels currently allocated to network interface.

"Procedure

To clear DS0 channel allocation:

1.Access the Cross Connect Assignments screen by following this menu selection sequence:

Main Menu Configuration Load Configuration From

Cross Connect

2.Select Ctrl-a and then Clrassign.

3.Press Enter to clear the specified DS0 channels.

3-6