Paradyne 7112 manual Extension to Interface Table ifXTable, IfName ifXEntry, IfXEntry

Models: 7112

1 156
Download 156 pages 11.03 Kb
Page 109
Image 109

MIB Descriptions

Table C-2. Interfaces Group Objects (5 of 5)

Object

Description

Setting/Contents

 

 

 

ifOutOctets

Collects output

An integer number.

(ifEntry 16)

statistics on data

 

1.3.6.1.2.1.2.2.1.16

received by the

 

 

interface.

 

ifOutUcastPkts

 

Applies to the FDL and

 

(ifEntry 17)

 

the Ethernet port.

 

1.3.6.1.2.1.2.2.1.17

 

Statistics are not

 

 

 

ifOutDiscards

collected if the

 

Ethernet port is

 

(ifEntry 19)

 

disabled.

 

1.3.6.1.2.1.2.2.1.19

 

 

 

 

 

 

ifOutErrors (ifEntry 20)

 

 

1.3.6.1.2.1.2.2.1.20

 

 

 

 

 

Extension to Interface Table (ifXTable)

This extension contains additional objects for the interface table. Supports only the following objects.

Table C-3. Extension to Interface Table (ifXTable) (1 of 2)

Object, OID, Access

Description

Setting/Contents

 

 

 

ifName (ifXEntry 1)

Provides name of the

Interface text strings:

1.3.6.1.2.1.31.1.1.1.1

interface.

H Ethernet Port

 

read-only

 

H Terminal Port

 

 

 

 

H Network

 

 

H Data Port

 

 

H FDL

 

 

 

ifLinkUpDown-

Indicates whether the link is

Only supports T1 network

TrapEnable

up or down, or enterprise-

and User data port.

(ifXEntry 14)

specific traps should be

SNMP Traps must be

 

generated.

1.3.6.1.2.1.31.1.1.1.14

enabled for the unit. See

 

read-write

 

Table A-10,SNMP Traps

 

 

Option.

 

 

 

7112-A2-GB20-20

March 1998

C-7

Page 109
Image 109
Paradyne 7112 manual Extension to Interface Table ifXTable, IfName ifXEntry, IfXEntry