Monitoring the DSU/CSU

Health and Status Messages

The following messages appear in the first column of the System and Test Status screen. The highest priority Health and Status message also appears on all ATI screens on the bottom right.

Table 6-2. Health and Status Messages (1 of 2)

Message

What Message Indicates

What To Do

 

 

 

 

Loss Of Signal

No signal is being received.

1.

Verify that the network cable is

 

Local DSU/CSU network

 

securely attached at both ends.

 

problem. An LOS condition

2.

Contact network provider.

 

(175 consecutive zeros) has

 

 

 

 

been detected on the network

 

 

 

interface.

 

 

 

 

 

 

Out of Frame

DSU/CSU is detecting an out

1.

Wait for the condition to clear.

 

of frame condition. This

2.

Verify that the line framing format

 

occurs when two out of four

 

 

configuration option matches the

 

frame synchronization bits are

 

 

 

setting of the network.

 

in error.

 

 

 

 

 

 

3.

Contact network provider.

 

 

 

 

Alarm Indication

An Alarm Indication Signal

1.

Check the status of the far-end

Signal

(unframed all ones signal) is

 

device(s).

 

being received from the

2.

Contact network provider.

 

network interface.

 

 

 

 

 

 

 

Excessive Error

An Excessive Error Rate

1.

Contact network provider.

Rate

condition has been detected

 

 

 

on the network interface. The

 

 

 

condition is cleared when the

 

 

 

error rate falls below the

 

 

 

threshold value.

 

 

 

 

 

 

Yellow Alarm

A Yellow Alarm signal is being

1.

Check the status of the far-end

 

received from the network

 

device.

 

interface.

2.

Contact network provider.

 

 

 

 

 

 

Primary Clock

The primary clock has failed.

1.

Check the clock source

Failed

Timing for the DSU/CSU is

 

connector (DTE or Net).

 

provided by the internal clock.

2.

If the primary clock was derived

 

 

 

 

 

from the network, contact the

 

 

 

network provider.

 

 

 

 

FDL Link Down

The FDL communication

1.

Verify that the remote unit has

 

between the local and remote

 

FDL enabled.

 

DSU/CSU is not working.

2.

Contact network provider if

 

 

 

 

 

problem persists.

 

 

 

 

Device Fail

An internal error has been

1.

Select the Clear function from the

yyyyyyyy

detected by the operating

 

Status screen.

 

software. yyyyyyyy indicates

2.

Provide the 8-digit failure code

 

the 8-digit hexadecimal failure

 

code.

 

shown ( yyyyyyyy ) to your service

 

 

representative.

 

 

 

 

 

 

 

7112-A2-GB20-20

March 1998

6-7