Testing

"Procedure

To run a Monitor QRSS test:

1.Position the cursor at the Start command next to Monitor QRSS on the Network Tests screen.

2.If desired, use Ctrl-a to switch to the screen function key area and use the virtual function key r or R (ResetMon) to clear the error counter to zero. Press Ctrl-a to return the cursor to the Start command and press Enter.

The Start command is changed to Stop.

3.To manually stop the test, verify that the cursor is positioned at the Stop command and press Enter.

The Send and Monitor Pattern tests cannot be started when any loopback is already active on the network interface.

Running Data Port Tests

To access the Data Port Tests screen, follow this menu selection sequence:

Main Menu Test Data Port Tests

main/test/data

 

 

 

 

 

PARADYNE

Device Name:

 

 

 

 

 

Model: 7112

 

 

 

 

 

DATA PORT TESTS

 

 

 

Test

 

 

 

Command

Status

Result

 

Local Loopbacks

 

 

 

 

 

Data Terminal Loopback:

Start

Inactive

0:00:00

 

 

Data Channel Loopback:

Start

Inactive

0:00:00

 

 

Remote Loopbacks

 

 

 

 

 

Send V.54 Loopback: Up

Send

Inactive

0:00:00

 

 

 

 

 

 

 

 

 

 

Send FT1 Loopback: Down

Send

Inactive

0:00:00

 

 

Pattern Tests

 

 

 

 

 

Send:

QRSS

Start

Inactive

0:00:00

 

 

Monitor:

QRSS

Stop

Active

99:08:48 ± Errors 99999+

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±È±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit ResetMon

7112-A2-GB20-20

March 1998

7-7

Page 65
Image 65
Paradyne 7112 manual Running Data Port Tests, Main Menu → Test → Data Port Tests