MIB Descriptions

Asynchronous Port Table Objects

The Asynchronous Port Table Objects contains an entry for the Terminal port. For this unit, entries in the table that are counters (rs232AsyncPortEntry 6±8) are used to collect statistics only and are not supported.

Table C-12. Asynchronous Port Table Objects

Object, OID, Access

Description

Setting/Contents

 

 

 

rs232AsyncPortBits

Specifies the number of bits

Supports only the following

(rs232AsyncPortEntry 2)

in a character.

values:

1.3.6.1.2.1.10.33.3.1.2

 

7 ± 7-bit characters

read-write

 

8 ± 8-bit characters

 

 

 

 

 

rs232AsyncPortStopBits

Specifies the number of

Supports only the following

(rs232AsyncPortEntry 3)

stop bits supported.

values:

1.3.6.1.2.1.10.33.3.1.3

 

one(1) ± One stop bit

read-write

 

two(2) ± Two stop bits

 

 

 

 

 

rs232AsyncPortParity

Specifies the type of parity

Supports only the following

(rs232AsyncPortEntry 4)

used by the port.

values:

1.3.6.1.2.1.10.33.3.1.4

 

none(1) ± No parity bit

read-write

 

odd(2) ± Odd parity

 

 

 

 

even(3) ± Even parity

 

 

 

rs232AsyncPortAuto-

Specifies the ability to

Supports only the following

Baud

automatically sense the

values:

(rs232AsyncPortEntry 5)

input speed of the port.

disabled(2) ± Does not

 

 

1.3.6.1.2.1.10.33.3.1.5

 

support Autobaud.

read-write

 

 

 

 

 

C-22

March 1998

7112-A2-GB20-10

Page 124
Image 124
Paradyne 7112 manual Asynchronous Port Table Objects, Rs232AsyncPortEntry, Disabled2 ± Does not