MIB Descriptions

Table C-11. General Port Table Objects

Object, OID, Access

Description

Setting/Contents

 

 

 

rs232PortType

Identifies the port hardware

Supports only the following

(rs232PortEntry 2)

type.

values:

1.3.6.1.2.1.10.33.2.1.2

 

rs232(2) ± Identifies the

read-only

 

Terminal port.

 

 

v35(5) ± Identifies the

 

 

synchronous User Data port

 

 

which is compatible with the

 

 

V.35 standard.

 

 

 

rs232PortInSigNumber

Contains the number of

The value is 2 for synchronous

(rs232PortEntry 3)

input signals (in the input

user data port and 0 for the

1.3.6.1.2.1.10.33.2.1.3

signal table) that can be

Terminal port.

detected.

 

read-only

 

 

 

 

 

 

rs232PortOutSigNumber

Contains the number of

The value is 3 for synchronous

(rs232PortEntry 4)

output signals (in the output

User Data port and 0 for the

1.3.6.1.2.1.10.33.2.1.4

signal table) that can be

Terminal port.

asserted.

 

read-only

 

 

 

 

 

 

rs232PortOutSpeed

Contains the port's output

Supports the following speeds

(rs232PortEntry 6)

speed in bits per second.

for the Terminal port: 2400,

1.3.6.1.2.1.10.33.2.1.6

The rs232PortOutSpeed

4800, 9600,14,400, 19,200,

28,800, 38,400.

read-write

object has the same values

 

 

as the rs232PortInSpeed

 

 

object.

 

 

 

 

The following are not supported:

Hrs232PortInFlowType (rs232PortEntry 7)

Hrs232PortOutFlowType (rs232PortEntry 8)